Up ] NRV ] FTV ] BFV ] HGC ] [ WCV ]

 

Wafer check valves

 

Normex, pioneers and manufacturers of unique Ball Check Valves, Ball Foot Valves, Hydrodynamic Guided NRVS have introduced yet another design of Non-return valve Wafer check Valves. Normex wafer check valves are simple in construction have sturdy design & are reliable in operations. These valves are very useful where weight of the valve is required be low & there is a space constraint for valve fitment. The face to face distance in these valves is extremely less as compared to standard valves.

Normex Wafer check valves

Model : WCV / WSP

n 100% leak proof

n Short length - less space required.

n Light weight.

n Low opening & closing pressures.

n Wide range of materials, temperature & pressure ratings

n Efficient flow characteristics.

n Highly economical.

 

 

Salient Features

n Sturdy but simple design.
n 100% leak proof
n Short length - less space required.
n Light weight.
n Lower pressure drop across the valve.
n Low opening & closing pressures.
n Wide range of materials, temperature & pressure ratings
n Efficient flow characteristics.
n Can be mounted horizontally & vertically.
n Highly economical.
n Epoxy coating over the entire surface.

 

 

Part List / Materials of Construction

 

Part

Standard Material

Optional Material

1. Body

CI/MS

CS, SS

2. Disc

MS

SS

3. 'O' ring

Nitrile

EPDM, Neoprene, Viton

 

 

Dimension Chart

 

Size

Ø B

Ø D

L
(for Type WCV)

mm

in

40

  1.5

22

81

16

50

2

30

96

16

65

  2.5

40

109

16

80

3

52

130

16

100

4

71

160

16

125

5

93

190

16

150

6

114

213

19

200

8

157

270

28

250

10

195

327

28

300

12

230

377

38

350

14

270

437

41

400

16

310

487

51

450

18

360

532

51

500

20

406

585

60

600

24

490

687

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Data

 

Pressure Rating

PN 10 & PN 16

Types 

Without spring (WCV) & spring loaded (WSP)

Sizes

40mm to 600mm

PN rating 

PN10, PN16,

Temperatur 

20*.C to 220'C

Installation 

Horizontal /Vertical

Flanges 

Between any standard flanges

 

 

 

Installation

 

1) Normex Wafer Check valves can be installed between any two standard flanges.
2) The outside diameter of valve is designed considering the minimum P.C.D. available in various flange standards.
3) The valve should be centered between the outside diameter of the pipe flanges simultaneously while tightening the bolts.
4) Recheck that valve outside diameter is equidistant to flange diameter on all sides and fully tighten the bolts.

 

 

 

 

 

 

 

 

 

 

 